Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

4.1.8.15.(2)
OS2OP2
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Seismic Force Resisting Systems with discontinuous columns, walls or braced frames for buildings where IEFaSa(0.2) is equal to or greater than 0.35.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A and to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] that are required to be designed in accordance with the requirements of Part 4.
Top of Page
Intent
Intent 1: 
To limit the probability that the design of elements supporting a discontinuous column, wall or braced frame will not be based on the capacity of the discontinuous element, which could lead to yielding in the discontinuity, which could lead to a sudden brittle failure, which could lead to harm to persons.