Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

4.1.8.16.(5)
OS2OP2OS2OP2
ObjectiveOS2 Structural Safety
Attribution
(a) [F20-OS2.1]
Application
Application 1: 
Design of piles, drilled piers, and caissons when the design moment in the element due to earthquake effects is greater than 75% of its moment capacity, at sites where IEFaSa(0.2) is greater than 0.75.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A and to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] that are required to be designed in accordance with the requirements of Part 4.
Top of Page
Intent
Intent 1: 
To limit the probability that the deep foundation elements will not be able to accommodate cyclic inelastic behaviour, which could lead to structural failure, which could lead to harm to persons.