Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
4.1.8.17.(6) | Application | Intent |
OS2 | OP2 |
Objective | OS2 Structural Safety |
Attribution | |
Application | Application 1: Determination of the storey seismic
lateral forces where floors or roofs support a tank whose mass, including
contents, is greater than 10% of the mass of the floor or roof, in areas where
IEFaSa(0.2) is equal to or greater than 0.35
or in post-disaster buildings.
Exceptions:
|
Top of Page | |
Intent | Intent 1: To limit the probability that the inertial seismic force
applied by a tank to the building structure for structural design will not
take into account the dynamic response of the tank containing liquid when
subjected to the maximum expected seismic building motions, which could lead
to structural failure, which could lead to harm to persons. |