Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

5.1.4.1.(1)
OH1OS3OH4OS2OS1OS2OH1OH4
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Resistance to deterioration and environmental loads, as well as the effects of those loads, of building materials, components, assemblies and their interfaces described in Sentence 5.1.2.1.(1) that are installed in buildings to which Part 5 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 5].
Application 2: 
This also applies to cladding assemblies installed on buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] where:
  • the cladding assembly is not addressed in Section 9.27., or
  • the cladding assembly does not comply with the prescriptive requirements of Section 9.27.
Application 3: 
This also applies to the position of low air and vapour permeance materials within the building assembly relative to the position of materials providing thermal resistance in the assemblies of buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where the building assembly:
  • incorporates low permeance materials that act as other than cladding or that are installed on the warm side of the assembly, and
  • is more susceptible to condensation [see Sentences 9.25.1.2.(4) and (5) for combinations of interior and exterior environmental conditions that create a higher risk for condensation].
Application 4: 
This also applies to the design of vapour barriers in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where the building assembly is more susceptible to condensation [see Sentences 9.25.4.2.(2) and (3) for combinations of interior and exterior environmental conditions that create a higher risk for condensation].
Top of Page
Intent
Intent 1: 
To limit the probability of an inadequate resistance to expected environmental loads and deterioration, which could lead to:
  • air infiltration and exfiltration,
  • excessive heat loss or gain,
  • condensation,
  • precipitation ingress,
  • moisture ingress from the ground, or
  • pollutant ingress, including soil gas, combustion products from parking garages, or particulates.
This is to limit the probability of:
  • the inadequate control of temperatures of interior spaces, drafts, relative humidity or water accumulation,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to further compromised integrity of environmental separators.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.