Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

5.10.1.1.(2)
+
Application
Application 1: 
Flame-spread properties of thermal insulation materials and components and interfaces between those components and assemblies.
This applies to building materials, components, assemblies and their interfaces described in Sentence 5.1.2.1.(1) that are installed in buildings to which Part 5 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 5].
Top of Page
Intent
Intent 1: 
To exempt materials, components and assemblies installed to resist the transfer of heat from the requirements regarding flame-spread ratings contained in the thermal insulation standards referenced in Table 5.10.1.1., on the basis that the rating is not necessary for the adequate thermal performance of such materials, components and assemblies.
Intent 2: 
To direct Code users to Part 3 for requirements regarding flame-spread ratings, which may apply to the materials, components or assemblies in question.