Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

5.10.1.1.(3)
+
Application
Application 1: 
Wired glass assemblies installed in required fire separations in building assemblies.
This applies to building materials, components, assemblies and their interfaces described in Sentence 5.1.2.1.(1) that are installed in buildings to which Part 5 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 5].
Top of Page
Intent
Intent 1: 
To exempt certain wired glass assemblies from the application of Sentence (1), on the basis that fire resistance is a more important property than watertightness and it is recognized that wired glass assemblies that provide the required fire resistance may not necessarily meet the watertightness criteria.