Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

5.8.2.2.(5)
+OH1OS2
Application
Application 1: 
Design and construction of materials and components installed to provide the required protection from moisture transfer from the ground into or through building assemblies, and through interfaces between assemblies, that separate interior space from the ground, in buildings to which Part 5 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 5].
Exceptions: 
except as stated in:
  • Sentence 5.8.2.1.(2), which applies where a lack of resistance to moisture transfer from the ground will not adversely affect health, safety, the intended use of the building or the operation of building services, and
  • Sentence 5.8.2.2.(7), which applies to assemblies that:
    • are constructed of cast-in-place concrete,
    • have a drainage layer installed between the assembly and the soil to reduce moisture loading, and
    • are not exposed to hydrostatic pressure.
Top of Page
Intent
Intent 1: 
To direct Code users to Section 4.2. for the accepted method for determining hydrostatic pressure with respect to the direct consequences of non-compliance with the objectives of Structural Safety and Structural Sufficiency of the Building.