Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
6.2.2.3.(1) | Application | Intent |
OS3 |
Objective | OS3 Safety in Use |
Attribution | |
Application | Application 1: Mechanical ventilation systems for enclosed storage garages serving buildings to
which Part 6 applies [see Sentence 1.3.3.2.(1) of Division A for application
of Part 6]. Application 2: This also applies to buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9], with respect to the ventilation of storage
garages for more than 4 motor vehicles in residential
occupancies, as stated in Sentence 9.32.1.1.(3).
Exceptions:
except as stated in:
|
Top of Page | |
Intent | Intent 1: To limit the probability of inadequate ventilation, which
could lead to excessive levels of carbon monoxide gas or nitrogen dioxide
in storage garages, which could lead to the acute poisoning or asphyxiation
of persons. |