Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

6.2.2.7.(1)
OH1
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Ventilation of unconditioned and unoccupied crawl spaces and attic or roof spaces, in buildings described in Sentence 1.3.3.2.(1) of Division A.
Top of Page
Intent
Intent 1: 
In attic or roof spaces, to limit the probability that inadequate ventilation will lead to:
  • the formation of ice dams, which could lead to the ingress into attic or roof assemblies of water backed up by ice dams, or
  • the inadequate control of relative humidity, which could lead to condensation and moisture accumulation.
This is to limit the probability of harm to persons.
Intent 2: 
In crawl spaces, to limit the probability that inadequate ventilation will lead to condensation, moisture accumulation, or moisture ingress from the ground.
This is to limit the probability of the growth of mould and mildew, which could lead to:
  • negative effects on the air quality of indoor spaces, and
  • contact with moisture.
This is to limit the probability of harm to persons.