Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.3.1.1.(2)
+
Application
Application 1: 
Design, mixing, placing and curing of site-batched, cast-in-place concrete that is not required to be reinforced that is used in:
  • footings, foundation walls, walls, columns, grade beams and piers,
  • basement floors, crawl space ground cover, garage and carport floors,
  • exterior steps, including steps providing structural support (to guards or handrails, for example), and
  • fireplaces and chimneys.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except as stated in Sentence 9.3.1.3.(1), which applies to concrete in contact with sulphate soil.
Top of Page
Intent
Intent 1: 
To state the application of Article 9.3.1.2. to 9.3.1.9.
Intent 2: 
To exempt site-batched concrete from compliance with CAN/CSA-A438 as required by Sentence (1) for cast-in-place concrete.