Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.3.2.9.(1)
OS2OP2OH1OH4OS3OS1
ObjectiveOH1 Indoor Conditions
Attribution
[F82,F80,F61,F55-OH1.1,OH1.2] [F82,F80,F61-OH1.3] Applies where structural wood elements support or are used in an environmental separator.
Application
Application 1: 
Structural wood elements, in localities where termites are known to occur, with respect to:
  • the resistance of structural wood elements to termites,
  • clearances between structural wood elements and the ground immediately below them, and
  • the visibility of supporting elements.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except as stated in Sentence 9.3.2.9.(2), which applies to the protection of assemblies supporting structural wood elements and their visibility.
Top of Page
Intent
Intent 1: 
To limit the probability of an inadequate resistance to termites or an inability to detect and mitigate termite infestations, which could lead to damage to wood elements, which could lead to an inability to resist expected gravity or lateral loads.
Where structural wood elements support or are used in an environmental separator, this is to limit the probability of compromised performance of the building envelope, which could lead to:
  • condensation,
  • precipitation ingress, or
  • compromised thermal performance of components intended to provide resistance to heat transfer.
This is to limit the probability of:
  • an inadequate control of indoor air and surface temperatures, drafts, relative humidity, or water accumulation,
  • the generation of pollutants from biological growth or from materials that become unstable upon wetting, or
  • deterioration, which could lead to further compromised integrity of environmental separators.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.