Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.3.1.7.(1)
OS2OP2OH1OH4OS3OS1OS2OP2OH1OS3OS2OS3OP2
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Mixes for site-batched, cast-in-place concrete that is not required to be reinforced that is used in floors, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except as stated in Clause 9.3.1.7.(1)(c), which applies to concrete for garage and carport floors where exposure to de-icing salts, water from rain or melting snow, freezing and thawing stresses, traffic, abrasion or other severe exposure conditions is likely.
Top of Page
Intent
Intent 1: 
To limit the probability of:
  • an inappropriate cement/aggregate ratio, or
  • excessive water in concrete.
This is to limit the probability of:
  • aggregate segregation,
  • reduced compressive strength,
  • increased shrinkage and cracking, or
  • low resistance to air and moisture transfer.
Where concrete is used in an environmental separator, this is to limit the probability of:
  • the compromised integrity of the environmental separator, or
  • an inadequate resistance to air and moisture transfer through the concrete.
This is to limit the probability of:
  • pollutant ingress (from the exterior, including soil gas)
  • condensation,
  • the ingress of moisture from the ground, or
  • the compromised thermal performance of components intended to provide resistance to heat transfer.
This is to limit the probability of:
  • the generation of pollutants from biological growth or from materials that become unstable on wetting,
  • deterioration, which could lead to further compromised integrity of environmental separators, or
  • an inadequate control of indoor air and surface temperatures, drafts, relative humidity, or water accumulation.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.