Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.6.4.1.(1)
OS3
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Protection for doors, in buildings of residential occupancy to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where the finished floor on one side of the door is more than 600 mm above the finished floor, other constructed surface or ground level on the other side of the door.
Top of Page
Intent
Intent 1: 
At significant changes in elevation between adjacent surfaces, to limit the probability:
  • that doors will unintentionally open to their full width, which could lead to inadequate fall protection, or
  • that doors will open greater than 100 mm, which could lead to inadequate fall protection for small children.
This is to limit the probability of persons falling, which could lead to harm to persons.
Intent 2: 
To expand the application of Subsection 9.8.8. to include guards for doors.