Warning This information has been archived because it is outdated and no longer relevant.

Archived Content

Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.8.2.2.(1)
OS3
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Minimum clear height over stairs, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Application 2: 
This also applies to stairs within dwelling units in buildings to which Part 3 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 3], as stated in Sentence 3.3.4.7.(1).
Top of Page
Intent
Intent 1: 
To limit the probability of insufficient clear height over stairs:
  • in dwelling units (1.95 m), where occupants are likely to be intimately familiar with their surroundings, or
  • in other than dwelling units (2.05 m), where occupants might not be familiar with their surroundings.
This is to limit the probability of:
  • persons accidentally contacting the ceiling with their head, or
  • persons accidentally contacting the ceiling with their head in an emergency, which could lead to persons falling, which could lead to delays in the evacuation or movement of persons to a safe place.
This is to limit the probability of harm to persons.
Top of Page