Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.8.6.2.(3)
+
Application
Application 1: 
Landings at the top of exterior stairs serving a secondary entrance to a single dwelling unit, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where
  • the stair does not contain more than 3 risers,
  • the principal door is a sliding door or swings away from the stair, and
  • only a storm or screen door, if any, swings over the stair and is equipped with hardware to hold the door open.
Exceptions: 
except:
  • for landings at entrances from attached garages, and
  • as stated in Sentence 9.8.6.1.(2), which applies to landings in pedestrian ramps in barrier-free paths of travel.
Top of Page
Intent
Intent 1: 
To exempt certain stairs from the application of Sentence 9.8.6.2.(1), which would otherwise require a landing, in situations where an entrance with a safer configuration is provided and where users are likely to be familiar with the conditions.
Top of Page