Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.8.8.3.(4)
OS3
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Minimum height of all guards for flights of steps in required exit stairs (therefore excluding landings), in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except:
  • for flights of steps in required exit stairs (therefore excluding landings),
  • as stated in Sentence 9.8.8.3.(2), which applies to interior guards within dwelling units,
  • as stated in Sentence 9.8.8.3.(3), which applies to exterior guards serving not more than one dwelling unit and serving a walking surface not more than 1 800 mm above the finished ground level, and
  • as stated in Clause 3.8.3.4.(1)(e), which applies to barrier-free design in buildings described in Sentence 3.8.1.1.(1) [see Sentence 9.5.2.1.(1)].
Top of Page
Intent
Intent 1: 
To limit the probability that guards will not be high enough to provide reasonable fall protection, which could lead to:
  • persons falling, or
  • persons falling in an emergency, which could lead to delays in the evacuation or movement of persons to a safe place.
This is to limit the probability of harm to persons.
Intent 2: 
To supersede the guard height requirement stated in Sentence (1), in cases where the risk of falls and injury is reduced because occupants are likely to be familiar with their surroundings.