Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.8.8.6.(2)
OS3
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Climbability of guards required by Article 9.8.8.1. [see Sentence 9.8.8.1.(1) for locations of required guards ], in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except:
  • in industrial occupancies where it can be shown that the location and size of openings do not represent a hazard, and
  • as stated in Clause 3.8.3.4.(1)(e), which applies to barrier-free design in buildings described in Sentence 3.8.1.1.(1) [see Sentence 9.5.2.1.(1)].
Application 2: 
This also applies to guards within dwelling units in buildings to which Part 3 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 3], as stated in Sentence 3.3.4.7.(1).
Top of Page
Intent
Intent 1: 
To limit the probability that children will climb guard elements and fall back over the top, which could lead to harm to persons.
Intent 2: 
To provide prescriptive criteria as an alternative to the requirement of Sentence 9.8.8.6.(1).