Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.9.6.4.(4) | Application | Intent |
+ |
Application | Application 1: Movable partitions that
are used to separate a public corridor from
an adjacent business and personal services occupancy or
a mercantile occupancy and that are not located
in the only means of egress, in buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9]. |
Top of Page | |
Intent | Intent 1: To exempt from the application of Sentence 9.9.6.4.(1) movable
partitions that are between a public corridor and an adjacent occupancy, on
the basis that there is an alternate means of egress available that does not
pass through the location where the movable panels are used so occupants would
not be impeded in their egress. |
Top of Page |