Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.9.6.7.(4) | Application | Intent |
OS3 |
Objective | OS3 Safety in Use |
Attribution | |
Application | Application 1: Automatic locking of doors opening onto public
corridors that provide access to exit from suites, where such doors are equipped with automatic self-closing
devices, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions:
except for hotels and motels.
|
Top of Page | |
Intent | Intent 1: To limit the probability that a person leaving a suite in
an emergency situation will be unable to return to the suite if they encounter
untenable conditions in the egress routes because the door will have shut
and lock itself behind them, which could lead to harm to persons.
|