Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.9.8.6.(1)
OS1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Means of egress leading to exits from spaces above mezzanines, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except as stated in:
  • Sentence 9.9.8.6.(2), which applies to mezzanines that
    • are not required to terminate at vertical fire separations, as permitted by Sentence 9.10.12.1.(2)
    • have an occupant load not more than 60
    • do not exceed the area limits for rooms and suites stated in Table 9.9.7.4., and
    • have limited travel distances to egress doors or stairways, and
  • Sentence 9.9.8.6.(3), which applies to one of the means of egress from a mezzanine that is not required to terminate at a fire separation, as permitted by Sentence 9.10.12.1.(2), and that exceeds the limits stated in Sentence (2).
Top of Page
Intent
Intent 1: 
To limit the probability that egress routes from a mezzanine will become untenable in a fire situation during the time involved in reaching the exits accessible at mezzanine level, which could lead to delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons.
Intent 2: 
To clarify that mezzanines are to be provided with exits on the same basis as required for floor areas.
Intent 3: 
To expand the application of Subsection 9.9.8. to mezzanines that are not included in the definition of floor area.