Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.9.8.6.(2) | Application | Intent |
+ |
Application | Application 1: Means of egress leading
to exits from mezzanines,
in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where:
Exceptions:
as permitted in Sentence 9.9.8.6.(3), which applies to one
of the means of egress from a mezzanine that
is not required to terminate at a fire separation,
as permitted by Sentence 9.10.12.1.(2), and that exceeds the limits stated
in Sentence (2).
|
Top of Page | |
Intent | Intent 1: To exempt exits serving certain mezzanines from the application
of Sentence 9.9.8.6.(1), which would otherwise require exits on the
same basis as required for floor areas, on the basis that the mezzanines are
relatively small and have a limited occupant load and travel distance, thus
allowing occupants to safely evacuate through the main floor level of the
storey containing the mezzanine. |