Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.14.4.(5) | Application | Intent |
+ |
Application | Application 1: Maximum aggregate area of unprotected
openings in an exposing building face of storage garages, where storage
garages have:
This applies to buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9].
|
Top of Page | |
Intent | Intent 1: To exempt open-air storage garages from the requirements
of Sentence 9.10.14.4.(1), which would otherwise limit the area of unprotected
openings, and permit unlimited unprotected openings, on the basis that the
fire load of the contents is relatively low, the space is well ventilated
and the limiting distance is not less than 3 m. |