Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.14.4.(6)
+
Application
Application 1: 
Maximum aggregate area of unprotected openings in an exposing building face of a storey, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where:
Exceptions: 
except as stated in Sentence 9.10.15.1.(1), which applies to buildings that contain only dwelling units and have no dwelling unit above another dwelling unit.
Top of Page
Intent
Intent 1: 
To exempt certain exposing building faces from the requirements of Sentence 9.10.14.4.(1), which would otherwise limit the area of unprotected openings, and permit unlimited unprotected openings, on the basis that the building face is readily accessible to firefighters [who will be able to effectively carry out fire suppression operations] and the limiting distance is not less than 9 m.