Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.14.5.(3) | Application | Intent |
OP3 |
Objective | OP3 Protection of Adjacent Buildings from Fire |
Attribution | |
Application | Application 1: Fire-resistance rating and
combustibility of exterior cladding of an exposing
building face of a garage or accessory building that:
This applies to buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9].
Exceptions:
except as stated in:
|
Top of Page | |
Intent | Intent 1: To supersede the requirements of Sentence 9.10.14.5.(1),
which might otherwise require a higher fire-resistance rating, if certain
conditions are met. This is to limit the probability
that an exposing building face will have insufficient fire resistance, which
could lead to the spread of fire from the subject building to an adjacent
building during the time required for emergency responders to perform their
duties, which could lead to damage to the adjacent building.
Intent 2: To exempt the exterior cladding of certain detached garages
or accessory buildings from the requirements of Sentence 9.10.14.5.(1),
which might otherwise require the cladding to be noncombustible, on the basis
that the accessory buildings and garages serve one dwelling unit only and
such structures are not expected to be normally occupied. |
Top of Page |