Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.14.5.(3)
OP3
ObjectiveOP3 Protection of Adjacent Buildings from Fire
Attribution
Application
Application 1: 
Fire-resistance rating and combustibility of exterior cladding of an exposing building face of a garage or accessory building that:
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except as stated in:
  • Sentence 9.10.14.3.(1), which applies to the calculation of the limiting distance where there are inadequate firefighting capabilities, and
  • Sentence 9.10.14.5.(4), which applies to detached garages and accessory buildings, where:
Top of Page
Intent
Intent 1: 
To supersede the requirements of Sentence 9.10.14.5.(1), which might otherwise require a higher fire-resistance rating, if certain conditions are met.
This is to limit the probability that an exposing building face will have insufficient fire resistance, which could lead to the spread of fire from the subject building to an adjacent building during the time required for emergency responders to perform their duties, which could lead to damage to the adjacent building.
Intent 2: 
To exempt the exterior cladding of certain detached garages or accessory buildings from the requirements of Sentence 9.10.14.5.(1), which might otherwise require the cladding to be noncombustible, on the basis that the accessory buildings and garages serve one dwelling unit only and such structures are not expected to be normally occupied.