Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.14.5.(4) | Application | Intent |
+ |
Application | Application 1: Fire-resistance rating,
type of construction and type of cladding for exposing
building faces of detached garages or accessory buildings facing
a dwelling unit, in buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9], where:
|
Top of Page | |
Intent | Intent 1: To exempt detached garages and accessory buildings facing
dwelling units from the requirements of Sentence 9.10.14.5.(1) and Sentence 9.10.14.5.(3), which would otherwise impose certain minimum requirements
relating to fire-resistance rating, type of construction and type of cladding
for exposing building faces, if certain conditions are met, on the basis that
detached garages and accessory buildings are considered an integral part of
a dwelling unit, and such structures are generally very small and the incidence
of fires in such structures in relation to house fires is low. There is insufficient
risk, therefore, to require the spatial separation of a house from its garage
or carport. |