Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.14.5.(7) | Application | Intent |
+ |
Application | Application 1: Minimum fire-resistance rating of
non-loadbearing wall components, where the limiting distance is 3 m or more, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] that are:
Exceptions:
except as stated in Sentence 9.10.14.3.(1), which applies to
the calculation of the limiting distance where
there are inadequate firefighting capabilities.
|
Top of Page | |
Intent | Intent 1: To exempt certain buildings from the requirements of Sentence 9.10.14.5.(1), which would otherwise impose certain minimum construction
requirements relating to fire-resistance rating and type of construction,
if certain conditions are met [i.e. the limiting distance is not less than
3 m]. This is on the basis that the risk of exposure of adjacent buildings
to fire is low due to the limitations on the type of occupancy, the type of
construction and the limiting distance. |