Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.15.2.(3) | Application | Intent |
+ |
Application | Application 1: Location of an exposing building
face for the purpose of determining the required type of construction,
cladding and fire-resistance rating of irregularly
shaped or skewed exterior walls, in buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9] that contain only dwelling units and
have no dwelling unit above another dwelling
unit.
Exceptions:
except as stated in Sentence 9.10.15.3.(1), which applies to
the calculation of the limiting distance where
there are inadequate firefighting capabilities.
|
Top of Page | |
Intent | Intent 1: To clarify how the location of an exposing building face
and the area of glazed openings is determined in Subsection 9.10.15.,
for the purpose of determining the type of construction and cladding and the
minimum fire-resistance rating for irregularly shaped or skewed exterior walls.
|
Top of Page |