Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.15.3.(1) | Application | Intent |
OP3 |
Objective | OP3 Protection of Adjacent Buildings from Fire |
Attribution | |
Application | Application 1: Calculation of limiting distance,
in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] that contain only dwelling units and have no dwelling
unit above another dwelling unit, where:
Exceptions:
except as stated in Sentence 9.10.14.5.(6) and Sentence 9.10.15.5.(6),
which apply to heavy timber and steel columns.
|
Top of Page | |
Intent | Intent 1: To supersede the requirements of Sentence 9.10.15.4.(1) and 9.10.15.5.(1), (2), (3) and (5), which require certain limiting distances, and require a greater
limiting distance if certain conditions are not met. This
is to limit the probability that fire will spread from the subject building
to an adjacent building during the time required for emergency responders
to perform their duties, which could lead to damage to the adjacent building.
|
Top of Page |