Warning This information has been archived because it is outdated and no longer relevant.

Archived Content

Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.12.2.2.(6)
+
Application
Application 1: 
Foundation depths for:
  • buildings that are of other than masonry or masonry veneer construction, and whose superstructure conforms to the requirements of the deformation resistance test in CAN/CSA-Z240.2.1, “Structural Requirements for Mobile Homes,” and
  • accessory buildings
    • that are not more than 1 storey in height,
    • that are not more than 55 m2 in building area, and
    • where the distance from finished ground to the underside of the floor joists is not more than 600 mm.
This applies to of buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To exempt from the application of Sentence 9.12.2.2.(1), which requires foundations to extend below the depth of frost penetration,
  • buildings for which surface foundations are suitable, and
  • small buildings that are not usually occupied and that represent little or no hazard to persons should they experience structural failure.
Top of Page