Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.12.3.3.(3)
OS2OP2OH1OS3
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Backfill for foundations, where foundation walls are:
  • cast-in-place concrete,
  • concrete block insulated on the exterior, or
  • concrete block protected from the backfill by a separation layer.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability of excessive lateral loading on foundation walls or jacking pressures from adfreezing to foundation walls, which could lead to movement or cracking of foundation walls.
This is to limit the probability of:
  • structural collapse of the foundation or of supported elements, or
  • where foundations act as or support environmental separators, compromised environmental separation elements, which could lead to:
    • condensation,
    • rainwater ingress, or
    • the ingress of moisture from the ground.
This is to limit the probability of the deterioration of protected or supported elements, which could lead to structural collapse, which could lead to harm to persons.
Top of Page