Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.13.3.1.(1)
OH1OS2
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Waterproofing of exterior surfaces of:
  • floors-on-ground that are subject to hydrostatic pressure, and
  • walls below ground level that are subject to hydrostatic pressure, where the finished ground level outside is higher than the ground level inside.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability of an inadequate resistance to water from the ground, under hydrostatic pressure, which could lead to:
  • the ingress of moisture from the ground, or
  • compromised thermal performance of components intended to provide resistance to heat transfer.
This is to limit the probability of:
  • an inadequate control of the temperature of interior spaces, relative humidity, or water accumulation,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to compromised integrity of elements supported or protected by floors-on-ground or foundation walls.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.