Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.13.4.3.(1)
OH1
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Control of the infiltration of soil gas at the wall-floor junction of masonry walls that are in contact with the ground and enclose interior space, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except as stated in Sentence 9.13.4.1.(2), which applies to:
  • walls that enclose garages, and
  • buildings located where soil gas is at a sufficiently low concentration as to not constitute a hazard.
Top of Page
Intent
Intent 1: 
To limit the probability of discontinuity between the materials installed to control the infiltration of soil gas in a floor-on-ground and the dampproofing (which serves as protection against the infiltration of soil gas) on the exterior of the masonry wall, which could lead to the infiltration of soil gas, which could lead to negative effects on the air quality of indoor spaces.
This is to limit the probability of harm to persons.