This information has been archived because it is outdated and no longer relevant.
Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.13.3.4.(3) | Application | Intent |
OH1 | OS2 |
Objective | OH1 Indoor Conditions |
Attribution | |
Application | Application 1: Removal of projections and filling of depressions
on the exterior of cast-in-place concrete walls that are in contact with the
ground and that are subject to hydrostatic pressure, where the ground level
outside is higher than the ground level inside, in buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9].
|
Top of Page | |
Intent | Intent 1: To limit the probability of an inadequate substrate, which
could lead to discontinuity in the waterproofing, which could lead to:
This is to limit the probability of:
This is to limit the probability of:
This is to limit the probability of harm to persons.
Intent 2: Where waterproofing materials are installed to control the
infiltration of soil gas, to limit the probability of an inadequate substrate,
which could lead to discontinuity in the waterproofing, which could lead to
the infiltration of soil gas, which could lead to negative effects on the
air quality of indoor spaces, which could lead to harm to persons.
|
Top of Page |