This information has been archived because it is outdated and no longer relevant.
Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.14.4.1.(1) | Application | Intent |
OS2 | OP2 | OH1 | OS2 | OP2 | OH1 | OH4 | OS3 |
Objective | OH1 Indoor Conditions |
Attribution | |
Application | Application 1: Granular material that is laid down to drain the bottom
of exterior foundation walls of buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9].
Exceptions:
except for:
|
Top of Page | |
Intent | Intent 1: To limit the probability of inadequate percolation, which
could lead to excessive moisture loading on foundation walls and basement
floors, which could lead to:
This is to limit the probability of:
This is to limit the probability of:
This is to limit the probability of harm to persons.
|
Top of Page |