Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.15.3.6.(1) | Application | Intent |
OS2 | OP2 | OH1 | OH4 | OS3 |
Objective | OP2 Structural Sufficiency of the Building |
Attribution | |
Application | Application 1: Minimum width of concrete strip footings for interior loadbearing masonry walls, for foundations for buildings to which Section 9.15. applies
[see Sentence 9.15.1.1.(1) for application of Section 9.15.].
Exceptions:
except as stated in:
|
Top of Page | |
Intent | Intent 1: To limit the probability of insufficiently wide strip footings,
which could lead to compressive failure and excessive settlement of underlying
soil, which could lead to structural damage to the foundation and the building,
which could lead to an inability to support vertical building loads or lateral
earth loads. This is to limit the probability of compromised
structural integrity, which could lead to:
This is to limit the probability of:
|
Top of Page |