Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.17.3.4.(2)
+
Application
Application 1: 
In buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]:
  • adjustable steel columns with allowable loads exceeding 36 kN, and
  • steel columns other than those that are used to support
    • beams carrying loads from not more than 2 wood-frame floors where:
      • the supported length of joists bearing on such beams does not exceed 5 m, and
      • the live load on any floor does not exceed 2.4 kPa
    • beams or header joists carrying loads from not more than 2 levels of wood-frame balconies, decks or other accessible exterior platforms, or 1 level plus roof, where:
      • the supported length of joists bearing on such beams or rim joists does not exceed 5 m,
      • the sum of the specified snow and occupancy loads on the platform-type construction or roof does not exceed 4.8 kPa,
      • the platform serves only a single suite of residential occupancy, and
      • the platform does not serve as a required exit, and
    • carport roofs.
Top of Page
Intent
Intent 1: 
To expand the application of Part 4 to include steel columns whose imposed loads are likely to exceed the resistance of the steel columns identified in Section 9.17.
Top of Page