Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.19.1.3.(2)
OH1OS2
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Clear air space between insulation baffles and the underside of the roof sheathing at the junction with exterior walls, in attic and sloped roof assemblies, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where insulation is installed above the ceiling and below the roof sheathing.
Exceptions: 
except as stated in:
  • Sentence 9.19.1.1.(1), where attic or roof space venting can be shown to be unnecessary, and
  • Sentence 9.19.1.4.(1), which applies to the lower portions of mansard or gambrel roofs.
Top of Page
Intent
Intent 1: 
To limit the probability of inadequate airflow through the vented space, which could lead to:
  • condensation in the space, or
  • the formation of ice dams, which could lead to the ingress of water.
This is to limit the probability of:
  • compromised thermal performance of components intended to provide resistance to heat transfer, which could lead to an inadequate control of the temperature of interior spaces,
  • water accumulation in interior spaces or an inadequate control of relative humidity,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to compromised integrity of ceilings acting as environmental separators.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.
Intent 2: 
To exempt junctions of sloped roofs and exterior walls where preformed baffles are installed from the minimum clear air space dimensions specified in Sentence 9.19.1.3.(1), based on the demonstrated effectiveness of a reduced unobstructed space provided by insulation baffles.