Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.20.17.3.(2)
OS2OP2OH1OH4OS3
ObjectiveOH1 Indoor Conditions
Attribution
[F20,F22-OH1.1,OH1.2,OH1.3] Applies to elements that support or are part of an environmental separator.
Application
Application 1: 
Minimum depth of concrete in portions of walls over openings in non-loadbearing flat insulating concrete form walls not in contact with the ground, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where:
  • the floor-to-floor height is not greater than 3 m,
  • the buildings are not more than 2 storeys in building height and they contain only a single dwelling unit, and
  • the buildings are erected in locations where the seismic spectral response acceleration, Sa(0.2), is not greater than 0.4.
Exceptions: 
except as stated in Sentence 9.20.1.1.(2), which applies to insulating concrete form walls other than those described above, or where the walls are designed for specified loads on the basis of ultimate and serviceability limit states.
Top of Page
Intent
Intent 1: 
To limit the probability of an insufficient depth of concrete across the width of openings to provide adequate flexural and shear capacity, and cover and bond for reinforcing steel, which could lead to an inability to resist transverse or vertical loads, which could lead to concrete cracking or the displacement of walls.
Where elements support or are part of an environmental separator, this is to limit the probability of:
  • condensation,
  • rainwater ingress,
  • the ingress of moisture, or
  • compromised thermal performance of components intended to provide resistance to heat transfer.
This is to limit the probability of:
  • an inadequate control of temperatures of interior spaces, relative humidity, or water accumulation,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to further compromised integrity of environmental separators.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.