Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.21.2.2.(4) | Application | Intent |
OH1 | OS3 |
Objective | OH1 Indoor Conditions |
Attribution | |
Application | Application 1: Connection to the same chimney flue of liquid-fuel-burning appliances and appliances burning natural gas or propane, where the appliances have a combined total rated heat output of 120
kW or less and rectangular masonry or concrete
chimneys are not more than 12 m in height, in buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9]. Application 2: This also applies to the connection to the same chimney flue of liquid-fuel-burning appliances and appliances burning
natural gas or propane, where the appliances have
a combined total rated heat output of 120 kW or less and rectangular masonry or concrete chimneys are not more than 12
m in height, in buildings to which Part
6 applies [see Sentence 1.3.3.2.(1) of Division A for application of
Part 6], as stated in Sentence 6.3.1.2.(1). |
Top of Page | |
Intent | Intent 1: To limit the probability that the ignition of a liquid-fuel-burning
appliance will lead to a relatively sudden increase in flue pressure, which
could lead to the spillage of combustion products from natural-gas- or propane-burning
appliances into living space, which could lead to negative effects on the
air quality of indoor spaces, which could lead to harm to persons.
|