Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.1.1.(1)
+
Application
Application 1: 
Light constructions where wall, floor and roof systems comprise lumber frames of small repetitive structural members or other engineered systems, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], and where:
  • roof and wall planes are clad, sheathed or braced on at least one side,
  • the small repetitive structural members are spaced not more than 600 mm o.c.,
  • constructions do not resist horizontal loads imposed by soil,
  • the specified live load on supported subfloors and floor framing does not exceed 2.4 kPa, and
  • the span of any structural member does not exceed 12.20 m.
Top of Page
Intent
Intent 1: 
To state the application of Section 9.23.
Top of Page