Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.23.4.4.(3) | Application | Intent |
OS2 | OP2 | OH1 | OS1 | OH4 | OS3 |
Objective | OS2 Structural Safety |
Attribution | |
Application | Application 1: Reduction in maximum spans for lumber beams or in
maximum supported length of floor joists used to support floors with a concrete
topping not more than 51 mm thick, in residential applications
or where the live load on any floor does not exceed 1.9
kPa, in wood-frame constructions to which Section 9.23. applies
[see Sentence 9.23.1.1.(1) for application of Section 9.23.].
|
Top of Page | |
Intent | Intent 1: To limit the probability of excessively long spans of beams
or joists, which could lead to beams being unable to resist the additional
weight of a concrete topping, which could lead to excessive deflection or
failure. This is to limit the probability of compromised
structural integrity, which could lead to:
This is to limit the probability of harm to persons.
|