Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.6.2.(3)
+
Application
Application 1: 
Anchorage of exterior columns and posts, or of supported joists or beams, in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application of Section 9.23.], where the columns or posts support balconies, decks, verandas or other exterior platforms, where the distance from finished ground to the underside of the joists is not more than 600 mm, and where the platforms:
  • are not more than one storey in height,
  • are not more than 55 m2 in area,
  • do not support a roof, and
  • are not attached to another structure unless it can be shown that differential movement will not adversely affect that structure.
Top of Page
Intent
Intent 1: 
To exempt certain platforms from the requirement for anchorage stated in Sentences 9.23.6.2.(1) and 9.23.6.2.(2), in cases where adverse effects from differential movement are unlikely to occur.
Top of Page