Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.14.4.(2)
OS3OP2OH4
ObjectiveOP2 Structural Sufficiency of the Building
Attribution
Application
Application 1: 
Orientation and alignment of OSB qualifying as construction sheathing, O-1 and O-2 grade OSB, and R-1 grade waferboard used as subflooring, in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application of Section 9.23.].
Top of Page
Intent
Intent 1: 
To limit the probability of inappropriate orientation or alignment of joints in OSB and waferboard subflooring, which could lead to insufficient strength between joists, which could lead to an inability to resist expected gravity loads, which could lead to excessive deflection, which could lead to the space being unsuitable for its intended use.