Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.25.1.2.(7)
+
Application
Application 1: 
Air spaces inboard of sheet or panel-type wall cladding, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where the cladding:
  • has an air leakage characteristic less than 0.1 L/(s•m2) at 75 Pa,
  • has a water vapour permeance less than 60 ng/(Pa•s•m2), and
  • is installed in a building assembly that is required to be insulated (see Article 9.25.2.1.).
Top of Page
Intent
Intent 1: 
To expand the application of the air space criteria stated in Clause 9.27.2.2.(1)(a) to air spaces required to be provided inboard of low air- and vapour-permeance cladding on walls (see Clause 9.25.1.2.(2)(c)).