Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.26.13.2.(1)
OS2OP2OH1
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Structural design of sheet metal roofing spanning between spaced supports, on roofs of buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability of inadequate stiffness or strength, which could lead to excessive deflection or the structural failure of sheet metal roofing under expected gravity loads.
This is to limit the probability of:
  • the structural failure of the roofing, or
  • precipitation or meltwater ingress, which could lead to the deterioration of roofs or assemblies protected by roofs, which could lead to compromised structural integrity.
This is to limit the probability of harm to persons.
Top of Page