Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.27.2.1.(2)
OS2OH1
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Design and construction of exterior walls to which Subsection 9.27.2. applies [see Article 9.27.1.1. for application of Subsection 9.27.2.].
Exceptions: 
except where exterior walls are protected from specific mechanisms of deterioration.
Top of Page
Intent
Intent 1: 
To limit the probability that environmental separators will deteriorate at an unacceptable rate, which could lead to their premature failure, which could lead to:
  • condensation,
  • precipitation ingress,
  • pollutant ingress, or
  • compromised thermal performance of components intended to resist heat transfer.
This is to limit the probability of:
  • an inadequate control of temperatures, drafts, relative humidity or water accumulation in interior spaces,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to further compromised integrity of environmental separators.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, or
  • contact with moisture.
This is to limit the probability of harm to persons.
Top of Page