Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.27.2.4.(1)
OS2OH1
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Minimum clearance between finished ground and cladding that is adversely affected by moisture, for cladding assemblies to which Subsection 9.27.2. applies [see Article 9.27.1.1. for application of Subsection 9.27.2.].
Top of Page
Intent
Intent 1: 
To limit the probability that precipitation or meltwater will splash, soak or pool against the lower portions of cladding, which could lead to the accelerated deterioration and premature failure of cladding.
This is to limit the probability of precipitation or meltwater ingress, which could lead to:
  • compromised thermal performance of components intended to provide resistance to heat transfer, which could lead to an inadequate control of the temperature of interior spaces or relative humidity,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to compromised integrity of exterior walls or elements protected by exterior walls.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, or
  • contact with moisture.
This is to limit the probability of harm to persons.
Top of Page