Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.32.2.3.(4)
OH1
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Design and installation of non-heating-season mechanical ventilation systems serving residential occupancies, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability that the performance of mechanical ventilation systems will fall significantly below expectations.
This is to limit the probability of the inadequate control of:
  • airborne pollutants,
  • oxygen and other components necessary for breathable air, or
  • relative humidity, which could lead to condensation, which could lead to the generation of pollutants from biological growth or from materials that become unstable on wetting.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces, or
  • the inadequate thermal comfort of persons.
This is to limit the probability of harm to persons.