Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.32.3.4.(7) | Application | Intent |
OH1 | OS3 |
Objective | OS3 Safety in Use |
Attribution | |
Application | Application 1: Connection of outdoor air supply
ducts that are:
This applies to outdoor air supply
ducts in self-contained heating-season mechanical ventilation systems
coupled to forced air heating systems serving single dwelling
units with 5 or fewer bedrooms that are supplied with electrical power
and a heating system, in buildings to which:
Exceptions:
except as stated in Sentence 9.32.3.1.(1), which applies to
heating-season mechanical ventilation systems designed to comply with CAN/CSA-F326-M.
|
Top of Page | |
Intent | Intent 1: To limit the probability that the full negative pressure
in the return air plenum will not be available to draw in outdoor air, which
could lead to the inadequate replacement of indoor air with outdoor air, which
could lead to the excessive depressurization of dwelling units by exhaust
fans, which could lead to the spillage of carbon monoxide gas from fuel-burning
appliances that are susceptible to spillage, which could lead to the acute
poisoning or asphyxiation of persons. |