Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.32.3.4.(8) | Application | Intent |
OH1 | OS2 |
Objective | OS2 Structural Safety |
Attribution | |
Application | Application 1: Auxiliary outdoor air supply fans connected to outdoor
air supply ducts in self-contained heating-season
mechanical ventilation systems coupled to forced air heating systems serving
single dwelling units with 5 or fewer bedrooms
that are supplied with electrical power and a heating system, in buildings to
which:
Exceptions:
except as stated in Sentence 9.32.3.1.(1), which applies to
heating-season mechanical ventilation systems designed to comply with CAN/CSA-F326-M.
|
Top of Page | |
Intent | Intent 1: [Clause (c)] To limit the probability that the outdoor air
supply flow will exceed the normal operating exhaust capacity of the principal
ventilation fan, which could lead to excessive positive pressure within the
dwelling unit, which could lead to condensation within the building envelope.
This is to limit the probability of deterioration of building elements,
which could lead to structural failure, which could lead to harm to persons.
|
Top of Page |